0

CALL : 866-739-6260

CALL : 866-739-6260

Event Detail

DeviceNet and RSNetWorx Configuration and Troubleshooting - Beaumont

  • Date

    Tue, Jul 17 2018 - Thu, Jul 19 2018

  • Time

    08:30 AM - 04:30 PM

  • Location

    The Reynolds Company - Beaumont

  • Address

    1375 West Cardinal Dr. Beaumont, Texas 77705

  • Cost

    $ 1690

 

DeviceNet and RSNetWorx Configuration and Troubleshooting

 

COURSE AGENDA

Day 1

  • Identifying DeviceNet Network Components
  • Designing a DeviceNet Cable System
  • Creating a DeviceNet Network Configuration
  • Commissioning Nodes on a DeviceNet Network
  • Configuring a 1756-DNB DeviceNet Scanner Module for a ControlLogix systems

Day 2

  • Mapping Inputs and Outputs to 1756-DNB Scanner Module on a DeviceNet Network (ControlLogix)
  • Managing DeviceNet EDS Files
  • Configuring the Automatic Device Recovery (ADR) Feature for a DeviceNet Network
  • Communicating on a DeviceNet Network Using Explicit Messaging with the ControlLogix platform
  • Integrated Practice: Modifying a DeviceNet Network Configuration

Day 3

  • Troubleshooting a DeviceNet Network Using RSNetWorx for DeviceNet Software
  • Troubleshooting Using DeviceNet and ControlLogix Hardware Indicators
  • Troubleshooting a DeviceNet Network Using RSLogix 5000 Software
  • Troubleshooting Duplicate Node Addresses on a DeviceNet Network
  • Integrated Practice: Restoring a Malfunctioning DeviceNet

 

Course Purpose

This course prepares students to successfully design and configure an efficient DeviceNet network using components for the ControlLogix® platform. To meet this objective, students begin by designing a cable system, and then configure a driver, a 1756-DNB scanner module for ControlLogix, and network devices. This course also prepares students to troubleshoot a malfunctioning DeviceNet network and return it to normal operation with minimum downtime. Students will first verify proper network installation and then perform both hardware and software-based tasks used to isolate DeviceNet problems. Students will also practice the tasks necessary to add and replace network devices. The specific hardware components used in the course include DeviceNet round and flat cable, taps, connectors, power supplies, scanner modules, and DeviceNet-compatible devices such as photoelectric sensors, operator interfaces, packaged I/O, and drives. The software components include RSNetWorx™ for DeviceNet, RSLinx®, and RSLogix 5000® software (for ControlLogix systems).

 

Who Should Attend

Individuals responsible for designing and configuring a new DeviceNet network in a ControlLogix system should attend this course. Individuals responsible for isolating and correcting problems or performing basic maintenance on a DeviceNet network in a ControlLogix system should also attend this course.

Click on the attachment below to see more information on the pre-requisites, technology requirements, and more.

 

RSVP REQUIRED

To RSVP Contact Irma Rodriguez

DeviceNet and RSNetWorx Configuration and Troubleshooting .pdf For more details, please contact Irma Rodriguez at 713-426-8354.


DeviceNet and RSNetWorx Configuration and Troubleshooting - Beaumont

Date: Tue, Jul 17 2018 - Thu, Jul 19 2018

Time: 08:30 AM - 04:30 PM

Location: The Reynolds Company - Beaumont

Address: 1375 West Cardinal Dr. Beaumont, Texas 77705

Event Coordinator: Irma Rodriguez


For more information, please visit the Event Detail page for this event.