FBN36TE030RV
GE* Actual product may vary from image
Record Plus represents the very latest in molded case circuit breaker design. Utilizing design features such as double-break rotary contact structures and advanced ablative materials to enhance interruption, Record Plus is capable of interrupting ratings up to 200kA (FB max is 150kA). High kAIC ratings, selective coordination, reduced arc flash energy, and current limitation embody the core design principles of Record Plus. FB 100 circuit breakers are supplied with factory installed non-user interchangeable thermal-magnetic trip units and ca n be supplie d with o r wit hout l ugs. FB breakers are available in 1-, 2- and 3-pole versions. Record Plus product numbers ending in R or R0 do not include lugs. An R1 suffix indicates that the breaker is supplied with line and load lugs, R2 indicates load lugs, and R3 indicates line lugs. RV suffixed product numbers include load lugs and line connections specifically designed for General Electric type AD panels. All frames use common internal accessories (auxiliary switches, UV releases, shunt trips, and bell alarms) UL listed for field installation. UL listed maximum short circuit ratings at 480VAC are 150kA for the 100A frames and 200kA for the 600A frames. Unless noted otherwise, all circuit breakers and accessories are listed in UL file number E11592. 30A MCCB 3P 600Y347
Details
MFG PART #:FBN36TE030RV
TRC Part #:GEDIFBN36TE030RV
UPC #:783164395150
Inventory
$ E
Details
MFG PART #:FBN36TE030RV
TRC Part #:GEDIFBN36TE030RV
UPC #:783164395150
Inventory
Attributes
Features
Documentation
Attributes
Brand:GE
Type:Type FBN
Voltage Rating:600Y/347 VAC
Amperage Rating:30 A
Frequency Rating:50/60 Hz
Interrupt Rating:150 kA at 240 VAC/65 kA at 480 VAC
Frame:FB100
Trip Type:LI/Thermal Magnetic
Number of Poles:3
Phase:3 ph
Actuator Type:Pivot/Toggle Handle
Connection Type:Load Lug/Panel
Wire Size:10 to 4 AWG
Mounting Type:Panel
Temperature Rating:-40 to 80 deg C
Dimensions:4.11 in W x 3.28 in D x 6.45 in H
Material:Plastic
Features
Broad product line to meet virtually any application need |
Reduced downtime |
A tripped breaker is easily spotted and can be immediately reset after the fault has been corrected |
Eliminates single phasing |
A common trip bar disconnects all poles simultaneously on both overload and short circuits |
Offers application flexibility through the use of a wide variety of accessory devices and special attachments |
Repetitive operation no fuses to replace |
Breakers can be repetitively tested |
Fuses must be destroyed to confirm calibration accuracy |
150 kA at 240 VAC, 65 kA at 480 VAC interrupt rating |