EWZ120
NSI* Actual product may vary from image
Tork 7 Day 1 Channel SPDT Astronomic Time Switch APPLICATIONS: Outdoor Signs Heating and Air Conditioning Lighting Security FEATURES: INPUT SUPPLY: 120-277 VAC 50/60Hz INPUT VOLTAGE: 12-277 VAC 50/60Hz OUTPUT DRY CONTACTS: SPDT POWER CONSUMPTION: 6VA Max. TIMING ACCURACY: Line Frequency SCHEDULING: 20 ON/OFF set points repeat each day. Minimum Setting 1 minute. NO. OF CHANNELS: 1 Channel DAYLIGHT SAVINGS: Automatic adjustment (can be omitted) ASTRONOMIC: Adjustable 10 degrees - 60 degrees Northern or Southern latitudes. Can be individually offset +/- 1-240 minutes from both sunset and sunrise times. LEAP YEAR: Automatic Compensation MANUAL OVERRIDE: Until the next regularly scheduled ON or OFF, automatic operation then resumes. CLOCK FORMAT: AM/PM. POWER OUTAGE BACKUP: Permanent schedule retention. Super-capacitor provides 4 days of real time backup. ENCLOSURE: Plastic Indoor/Outdoor NEMA 3R with lockable hasp. BRAND EQUIVALENT: Intermatic ET8115C, ET8215CR MANUFACTURER: Tork, UPC: 786261824714 CONTACT RATINGS: GENERAL PURPOSE: 24-277VAC. Rating NO: 40A INDUCTIVE: 120-277VAC. Rating NO: 40A BALLAST: 120VAC. Rating NO: 30A 208-277VAC. Rating NO: 20A TUNGSTEN: 120VAC. Rating NO: 15A PILOT DUTY: 120-277VAC. Rating NO: 720VA MOTOR LOAD: 120VAC. Rating NO: 1HP 208VAC. Rating NO: 1.5 HP 240-277VAC. Rating NO: 2HP RESISTIVE: 28VDC. Rating NO: 30A
Details
MFG PART #:EWZ120
McMc Part #:TORKEWZ120
UPC #:786261824714
Inventory
$446.03Ā E
Details
MFG PART #:EWZ120
McMc Part #:TORKEWZ120
UPC #:786261824714
Inventory
Attributes
Features
Documentation
Attributes
Brand:NSI
Amperage Rating:40 A
Dimensions:5.062 in L x 3.062 in W x 8.312 in H
Enclosure Type:NEMA 3R
HorsePower:1-1/2 hp, 2 hp
Mounting Type:Threaded
Number Of Poles:1
Temperature Rating:-40 to 149 deg F
Voltage Rating:120 to 277 VAC
Display Type:Digital LED
Series:EWZ
Contact Form:SPDT
Number Of Channels:1
Operation Mode:7 days
Time Setting:1 to 240 min
Features
20 On and Off set points for individual programs for each day of the week, minimum setting is 1 min |
Adjusts daily to changes in sunset time |
Adjustable 10 to 60 deg northern or southern latitudes can be individually offset +/-1 to 240 min from both sunset and sunrise times |
Automatic adjustment (can be omitted) |
Automatic leap year compensation |
Until the next regularly scheduled On or Off, automatic operation then resume |
AM/PM clock format |
Permanent schedule retention |
Super capacitor provides 4 days of real time backup |
16 to 8 AWG terminal range |